Addendum to ARI Standard 410-2001
3
Checklist Items
3
FAQs
3
Glossary Terms
Dec 11, 2025
Last Updated
Topics & metadata
This addendum modifies Section 6.4.1 of ARI Standard 410-2001 regarding air-side pressure drop limits.
ARI 410-2001: Addendum to ARI Standard 410-2001 - Enhancing HVAC Equipment Performance Verification
For HVAC engineers and product developers, ensuring the precise performance of air-handling equipment is paramount. Understanding and adhering to industry-leading standards like ARI 410-2001, and its subsequent addenda, is essential for delivering reliable and efficient systems. This addendum refines critical performance verification protocols, offering clarity on air-side pressure drop limitations for HVAC equipment.
What is ARI 410-2001?
ARI Standard 410-2001 establishes comprehensive performance testing procedures for air-conditioning and refrigeration equipment. Its primary purpose is to provide a consistent and objective method for verifying that manufactured units meet specified performance criteria. This addendum specifically addresses and clarifies a key aspect of these verification protocols.
Scope & Purpose
This addendum clarifies the acceptable tolerance for published air-side pressure drop values during performance testing of HVAC equipment. It governs the permissible deviation from stated specifications, ensuring that tested units align closely with design expectations. The scope specifically pertains to air-side pressure drop measurements during standardized testing and does not extend to other performance metrics or operational conditions outside of the defined test procedures.
Who Must Comply?
- • Primary audience: HVAC Engineers, Test Engineers, Product Managers, Design Engineers, and Compliance Officers involved in the specification, design, testing, and manufacturing of HVAC equipment.
- • Industries affected: HVAC Manufacturing, Building Services, Mechanical Engineering, and Facility Management.
- • Compliance nature: Recommended for best practice, and often mandatory when specified in contracts or by regulatory bodies.
- • Enforcement: Primarily through internal quality assurance departments, third-party testing labs, and specifiers during project procurement.
Key Requirements Overview
The addendum to ARI Standard 410-2001 introduces a precise guideline for air-side pressure drop verification. Key provisions include:
- • The standard requires that published air-side pressure drop values, determined through testing, must not be exceeded by a significant margin.
- • Professionals must ensure that tested values remain within a defined tolerance of the published specifications.
- • A specific limit is set: published values shall not be exceeded by more than 10% or 0.05 inches of water gauge (12.5 Pa), whichever of these two values is greater.
- • This ensures that actual equipment performance closely aligns with the design intent and user expectations for airflow resistance.
Related Standards & References
This addendum works in conjunction with the overarching ARI Standard 410-2001. For broader understanding of HVAC equipment performance, professionals may also refer to related standards such as those from ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) concerning psychrometrics and system design, and potentially other ARI standards that cover specific equipment types or testing methodologies. These complementary standards provide a robust framework for comprehensive HVAC system design and verification.
Copyright & official sources
This page provides educational summaries and compliance aids. For the official, legally binding standard text, please purchase the current edition from the original publisher. Acquiring original publications supports continued standards development and ensures you have the complete, authoritative document.